NOTE:

In the tables below, each column features a sorting arrow, click on the arrow to sort the column numerically/alphabetically etc.

PRESSURE REDUCING REGULATORS

SERIES NUMBERMAX INLET PRESSUREMAX OUTLET PRESSUREFLOW (CV)SENSING ELEMENTSINGLE STAGE / TWO STAGELOADING TYPEVENTINGPART NUMBER(S)
R0.1 SERIES1000020000.1pistonsingle stage30-10589
2300C SERIES3500600.04diaphragmsingle stagespring loadednon-venting50-12607
2300N SERIES500 (dependent upon configuration)600.04diaphragmsingle stagespring loaded, preset non-venting50-11361, 50-12010
2300S SERIES30001000.05diaphragmsingle stagespring loaded, presetnon-venting50-12771, 50-12908
2310C SERIES3000600.025diaphragmsingle stage, reduced supply pressure effectspring loadednon-venting50-12305, 50-12179 (preset outlet pressure, acorn nut)
2310N SERIES3000600.025diaphragmsingle stage, reduced supply pressure effectspring loadednon-venting50-12143
2310S SERIES30001500.05diaphragmsingle stage, reduced supply pressure effectspring loaded, preset non-venting50-12861 50-12897 (preset outlet pressure, acorn nut)
2500 SERIES35005000.2, 0.08diaphragmsingle stagespring loaded, preset non-venting50-11962, 50-12357, 50-13375, 50-12790
2500A SERIES3000150.08diaphragmsingle stagespring loaded non-venting50-11631
2500DL SERIES30005000.2, 0.08diaphragmsingle stagedome loadednon-venting50-11789
2500DLB SERIES3000500 (preset spring bias up to 150 psig)0.2, 0.08diaphragmsingle stagedome loaded, bias springnon-venting50-12473
2510 SERIES35005000.2diaphragmsingle stage, reduced supply pressure effectspring loadednon-venting50-12308
2550 SERIES30002500.2, 0.08diaphragmsingle stagespring loaded non-venting, self-venting50-11487, 50-13281
2550A SERIES3000150.08diaphragmsingle stagespring loaded captured bonnet vent50-12757, 50-12484
2600 SERIES350025000.2, 0.08pistonsingle stagespring loaded non-venting50-11628 50-11853-(Cv 0.30 option)
2610 SERIES350025000.2pistonsingle stage, reduced supply pressure effectspring loaded non-venting50-12482
2660 SERIES350010000.2, 0.08pistonsingle stagespring loadedcaptured, self-venting bonnet vent50-12539
2700 SERIES300060PRESET FLOW RATE: 0.25 LPM to 9.0 LPMpistonsingle stagefixed/presetnon-venting50-10454 50-10482 50-10809 50-10619 50-10554 50-12202 50-12085 50-11742
2701 SERIES3000 (dependent on inlet)80PRESET FLOW RATE: 0.1 LPM to 4.0 LPMpistonsingle stagefixed/presetnon-venting50-12641 50-12640 50-12727 50-13188
2780 SERIES1000 (dependent on inlet)60PRESET FLOW RATE: 0.25 LPM to 7.0 LPMpistonsingle stagefixed/presetnon-venting50-11519 50-11095 50-11022 50-11080
2790 SERIES3000 (dependent on configuration)500 (dependent on configuration)0.0025pistonsingle stagefixed/preset50-11398 50-12938
2800N SERIES30001502.0, 1.0diaphragmsingle stagespring loadednon-venting50-12056
2800P SERIES30005002.0, 1.0pistonsingle stagespring loaded, presetnon-venting50-12230 50-12231
2800PDL SERIES 300010002.0pistonsingle stagedome loadednon-venting50-12278
2860PDL SERIES300015002pistonsingle stagedome loadedcaptured venting50-12732
2800S SERIES30001502.0, 1.0diaphragmsingle stagespring loadednon-venting50-11493
2900 SERIES350015PRESET FLOW RATE: 0.3 LPN to 8.0 LPMpistonsingle stagepresetnon-venting50-11387 50-10385 50-11321 50-11840 50-11573 (two stage)
3000 SERIES10000100000.2, 0.06, 0.12pistonsingle stagespring loaded, preset self-venting, non-venting available30-10000 30-10212 (Large Ports, Panel Mounting Nuts) 30-10206 (Gas, 10K, Captured Vent)
3000AL SERIES10000100000.2, 0.12, 0.06pistonsingle stageair loadedcaptured venting30-10219G
3000DL SERIES10000100000.06, 0.12, 0.20, 0.30pistonsingle stagedome loadedcaptured venting30-10219DLG
3016 SERIES10000 (dependent on configuration)100002.0, 1.0pistonsingle stagespring loaded, preset self-venting30-10216 30-10225 30-10228
3016AL SERIES10000100001.0, 2.0pistonsingle stageair loadedcaptured venting30-10227 30-10225AL
3016DL SERIES10000100001.0, 2.0pistonsingle stagedome loadedcaptured venting30-10227DL 30-10225DL
3020 SERIES10000100000.2, 0.12, 0.06, 0.04, 0.3pistonsingle stagespring loaded self-venting, captured venting available30-10218G 30-10218GC (Captured Venting)
3023 SERIES15000150000.12, 0.06, 0.20, 0.30pistonsingle stagespring loaded, preset captured venting30-10213G
3023AL SERIES15000150000.12, 0.06, 0.20pistonsingle stageair loadedcaptured venting30-10229G
3023DL SERIES15000150000.06, 0.12, 0.20pistonsingle stagedome loadedcaptured venting30-10229DLG
3025 SERIES20000200000.04pistonsingle stagespring loaded, preset captured venting30-10215G
3025AL SERIES20000200000.043pistonsingle stageair loaded captured venting30-10215ALG
3025HPL SERIES2000015000.04pistonsingle stagehigh pressure loaded captured venting30-10614 30-10670
3025SL SERIES20000200000.04pistonsingle stagestacked air loadercaptured venting30-10862SL
3400 SERIES60006000.08, 0.20diaphragmsingle stagespring loadedself-venting, non-venting available30-10435
3500 SERIES600060000.2, 0.06pistonsingle stagespring loaded, preset non-venting50-12282
3500AL SERIES600040000.2, 0.06pistonsingle stageair loadedcaptured venting, optional non-venting design with bias spring50-12306 50-12398 (Non-venting with Bias Spring)
3500DL SERIES600010000.2, 0.06pistonsingle stagedome loadedcaptured venting50-12251
3560 SERIES10000100000.2, 0.06pistonsingle stagespring loaded captured venting30-10466
4050 SERIES30003015 SLPM (Air)two stagespring loaded, preset 50-12805
4300N SERIES30001000.041st stage piston, 2nd stage diaphragmtwo stagespring loaded, preset non-venting50-12070 50-11422 50-10790 50-12705
4300S SERIES30001000.0141st stage piston, 2nd stage diaphragmtwo stagespring loaded non-venting50-10364
4500 SERIES30002500.2, 0.08diaphragmtwo stagespring loaded non-venting50-11494
4600 SERIES600025000.2, 0.06pistontwo stagespring loaded non-venting50-13020
4700 SERIES300020PRESET FLOW RATE: 0.25 LPM to 9.0 LPMpistontwo stagefixednon-venting50-11806 50-12523 (yoke style)
4902 SERIES3000NAPRESET FLOW RATE: 3.0 LPM to 8.0 LPM with increased vacuumdiaphragmsingle stagevacuumnon-venting50-11030
4903 SERIES3000NAPRESET FLOW RATE: 3.0 LPM to 8.0 LPM with increased vacuumdiaphragmsingle stagevacuumnon-venting50-12186
5000 SERIES450025002.0, 1.0pistonsingle stagespring loaded non-venting50-11969 (Cv 2.0) 50-12403 (Cv 1.0)
5033DL/5060DL SERIES600060006.0, 3.3pistonsingle stagedome loadednon-venting30-10819
5050 SERIES10002005.0diaphragmsingle stagepreset, hand loadednon-venting50-12560 50-12860
5050DL SERIES10001005.0diaphragmsingle stagedome loadednon-venting50-12456
5050DLB SERIES10004005.0diaphragmsingle stagedome loaded, bias springnon-venting50-12510
50120DL SERIES6000600012.00pistonsingle stagedome loadednon-venting30-10638
50200DL SERIES6000600020.0pistonsingle stagedome loadednon-venting30-10894
50300DL SERIES6000600030.0pistonsingle stagedome loadednon-venting30-10868
6000 SERIES10000100000.30, 0.20, 0.12, 0.06pistonsingle stagespring loaded, preset captured venting30-10203
6000DL SERIES10000100000.3, 0.2, 0.12, 0.06pistonsingle stagedome loadedcaptured venting30-10219DL
6000FL SERIES300025000.06pistonsingle stagedome loadedcaptured venting30-10203FL
6000AL SERIES10000100000.2, 0.12, 0.06, 0.30pistonsingle stageair loadedcaptured venting30-10219
6020 SERIES10000100000.2, 0.12, 0.06, 0.30pistonsingle stagespring loadedcaptured venting30-10218C
6023 SERIES15000150000.20, 0.12, 0.06pistonsingle stagespring loaded, preset captured venting30-10213
6023AL SERIES15000150000.12, 0.06, 0.20pistonsingle stageair loadedcaptured venting30-10229
6023DL SERIES15000150000.06, 0.12, 0.20pistonsingle stagedome loadedcaptured venting30-10229DL
6025 SERIES20000200000.2, 0.12, 0.06pistonsingle stagespring loaded captured venting30-10215
6025AL SERIES20000200000.3, 0.12, 0.06pistonsingle stageair loadedcaptured venting30-10215AL
6250 SERIES35005000.2diaphragmsingle stagespring loaded non-venting50-12414
6250DLB SERIES30005000.2, 0.08diaphragmsingle stagedome loaded, bias springnon-venting50-12662
6500 SERIES600060000.2, 0.06pistonsingle stagespring loaded, preset non-venting50-12283
6500AL SERIES600040000.2, 0.06pistonsingle stageair loadedcaptured venting50-12370
6500DL SERIES600010000.2, 0.06pistonsingle stagedome loadedcaptured venting50-12225
6560 SERIES10000100000.2, 0.06pistonsingle stagespring loaded captured venting30-10340

BACK PRESSURE REGULATORS

SERIES NUMBERMAX CONTROL PRESSURE (PSIG)FLOW (CV)SENSING ELEMENTLOADING TYPEFEATURESPART NUMBER(S)
2100 SERIES5000.2, 0.14diaphragmspring loaded, or preset50-11998, 50-11187 (Tamper Proof Acorn Nut)
2100DLB SERIES6000.2, 0.14diaphragmdome loaded, bias spring50-12474
2150A SERIES1000.04, 0.20diaphragmspring loadedabsolute pressure 50-12682
2400 SERIES750.6diaphragmspring loaded, or presethigh sensitivity50-11306, 50-12568
2400DL750.6diaphragmdome loadedhigh sensitivity50-12671
3100 SERIES100000.2, 0.14, 0.06, 0.03pistonspring loaded30-10066G
3100AL SERIES100000.2, 0.14, 0.06, 0.03pistonair loaded30-10205G
3100DL SERIES60000.2, 0.14, 0.06pistondome loaded30-10211DG
3116 SERIES60001.0, 2.0pistonspring loaded30-10222G
3123 SERIES150000.06, 0.14, 0.20pistonspring loaded30-10223G
3123AL SERIES150000.06, 0.14, 0.20pistonair loaded30-10223AL
3125 SERIES200000.03, 0.06, 0.14, 0.20pistonspring loaded 30-10226G
5150 SERIES2005pistonspring loaded50-12800
5150AL SERIES2005.0pistonair loaded30-10230
6100 SERIES100000.2, 0.14, 0.06, 0.03pistonspring loaded30-10066
6100AL SERIES100000.2, 0.14, 0.06, 0.03pistonair loaded30-10205
6100DL SERIES60000.2, 0.14, 0.06pistondome loaded30-10211D
6116 SERIES60001.0, 2.0pistonspring loaded30-10222
6123 SERIES150000.06, 0.14, 0.20pistonspring loaded30-10223
6125 SERIES200000.03, 0.06, 0.14, 0.20pistonspring loaded30-10226
P91W SERIES30000.38, 0.17diaphragmdome loaded50-12253

***Our products are updated frequently, please contact a Premier representative for the most current product specifications.

H2 PRESSURE REDUCING REGULATORS

SERIES NUMBERPART NUMBER(S)MAX INLET PRESSUREMAX OUTLET PRESSUREFLOW (CV)SENSING ELEMENTSINGLE STAGE / TWO STAGELOADING TYPEVENTING
H2 3000 SERIESH30-1020610000100000.04, 0.06, 0.12, 0.20pistonsingle stagehand loadedcaptured venting
H2 3000AL SERIESH30-1021910000100000.06, 0.12, 0.20pistonsingle stageair loadedcaptured venting
H2 3016 SERIESH30-10228 H30-10225 H30-1021610000 dependent upon configuration10000 dependent upon configuration1.0, 2.0pistonsingle stagehand loadedcaptured venting, non-venting
H2 3016AL SERIESH30-10227600060002pistonsingle stageair loadedcaptured venting
H2 3016SL SERIESH30-10237SL15000150000.5, 1.0pistonsingle stagestacked air loadcaptured venting, non-venting
H2 3023 SERIESH30-1021315000150000.04, 0.06, 0.12, 0.20pistonsingle stagehand loadedcaptured venting
H2 3023AL SERIESH30-1022915000150000.04, 0.06, 0.12pistonsingle stageair loadedcaptured venting

H2 BACK PRESSURE REGULATORS

SERIES NUMBERPART NUMBER(S)MAX CONTROL PRESSUREFLOW (CV)SENSING ELEMENTSINGLE STAGE / TWO STAGELOADING TYPE
H2 3100 SERIESH30-10066100000.03, 0.06, 0.12, 0.20pistonsingle stagehand loaded
H2 3100AL SERIESH30-10205100000.03, 0.06, 0.12, 0.20pistonsingle stageair loaded
H2 3123 SERIESH30-10223150000.03, 0.06, 0.12, 0.20pistonsingle stagehand loaded